ENTROPIE® is a manufacturer of industrial boilers and boiler equipment.

On the area of 60 000 m², six production workshops carry out a full production cycle. Production capacity - 1000 boilers per year.
ENTROPIE TT200 steam boiler
• TT200 are steel gasfired, three-way steam boilers with a steam production capacity range from 1 to 30 t/h with a design pressure of 8, 12, 16 bar.

• Corrugated furnace, high cyclic strength.

• Maximum values of operating efficiency among boilers of this class.
ENTROPIE TT250 steam boiler
• TT250 are steel gasfired two-pass steam boilers with a steam production capacity of 500–3,000 kg/h with a pressure of 8 or 12 bar.

• Versatile front door design. The unique design of hinge assemblies allows you to select the opening direction as left/right.

• Burner mounting using a burner plate or extension flange. Full opening of the front door with the burner device.
Steam capacity up to 30,000 kg / h
350 factory employees
TÜV and EAC certificates
Plant area over 60,000 m2
We produce up to 1000 boilers per year
25 Year Warranty
STEAM AUXILIARY MODULES
DEAERATOR
EDA
Deaerating module for the complete series EDA
is intended for the water deaerating, i. e. removal of oxygen and free CO2 off the water feed for steam boilers.

Without deaeration, corrosive gases dissolved in the water are released inside the steam generator and cause corrosion of metal parts.

Deaerator should be utilized as the last stage of the water treatment system for steam boilers. Deaerator is optionally equipped with all the associated piping.
ECONOMIZER
ECO-PLUS
Stand-alone carbon steel economizers shall be used as the tail surface for heating up steam boilers with maximal operating pressure of 16 bar and intended to heat up the feed water with flue gas offtake.

Utilization of economizer enhances the steam boiler efficiency up to 4 % with the same fuel consumption and also mitigates harmful emissions of flue gas.

Economizer is optionally equipped with a bypass line and a damper to control the flow
of flue gas allowing to direct flue gas away from heat-exchanging surfaces.
Standard version of the economizer is intended to utilize gaseous/diesel fuel.
Other fuels are optional.
SUPERHEATER
ESH
Steam superheater is intended for overheating the steam above the bubble-point.
Steam superheater is essentially a heat exchanger connected to the exhaust gas of the boiler second pass on the heating side and to the saturated steam on the side being heated.

Steam superheater is optionally equipped with a damper starter, which allows the boiler to operate both in the start-up mode under the lower load and the sustained operation mode.
Steam superheater comes equipped with automatic control system for steam boiler ENTROPIE.
CHEMICAL WATER TREATMENT MODULE
EHS
Module is intended to support the water-chemical mode of boiler operation and to prevent boiler from scaling.
Module of chemical treatment is softening the initial water (deferrization is optional).

Instructions on the maximal admissible hardness of the boiler water are outlined in Operation Manual.
The modular design helps to quickly perform installation/disassembly of the system and greatly reduce the commissioning period.
DEAERATOR
EDA
Deaerating module for the complete series EDA
is intended for the water deaerating, i. e. removal of oxygen and free CO2 off the water feed for steam boilers.

Without deaeration, corrosive gases dissolved in the water are released inside the steam generator and cause corrosion of metal parts.

Deaerator should be utilized as the last stage of the water treatment system for steam boilers. Deaerator is optionally equipped with all the associated piping.
CHEMICAL WATER TREATMENT MODULE
EHS
Module is intended to support the water-chemical mode of boiler operation and to prevent boiler from scaling.
Module of chemical treatment is softening the initial water (deferrization is optional).

Instructions on the maximal admissible hardness of the boiler water are outlined in Operation Manual.
The modular design helps to quickly perform installation/disassembly of the system and greatly reduce the commissioning period.
COOLER BUBBLER
EBR
Cooler-bubbler is intended to cool down hot blowdown water of a single-boiler/multi-boiler unit.

The design enables to control temperature of the water drainage. This can be achieved both through the automatic system of ENTROPIE and locally installed thermostat.
Cooling is achieved through mixing of initial and cooling water.

Cooler bubbler EBR is offered with five sizes, to fit every steam boiler.
CONDENSATE COLLECTOR SYSTEM
EСD
Condensate collector system shall enable efficient and uninterrupted operation of the boiler condensate system. The system is intended to collect condensate, which is received from the steam consumers.

Use of the ENTROPIE condensate collection and return system allows to reduce both feed water consumption and energy consumption for heating up.

Optional delivery set includes a condensate pump module and automated control system for the incoming condensate.
SEPARATOR
ECP
Separators of uninterrupted and intermittent purging are intended to separate into steam and water of steam-water mixture generated by blowdown water of steam boilers, condensate of steam receivers and drainage of steam lines when pressure of the blowdown water reduces to the pressure inside separator, followed with further utilization of the water/steam heat.

Separator is a vertically installed cylinder vessel of welded design and consists of a case and the two elliptical heads. The upper elliptical head is connected to the case via a flange.

Fixed to the case bottom are the supports for mounting the separator on the foundation. There are also padeyes for strapping the separator during cargo-handling and installation activities.
AUTOMATED WATER SAMPLING MODULE
ETH
Uninterrupted and reliable operation of boilers greatly depends on the quality and timely control of the boiler water/feed water. Module-water analyzer by ENTROPIE enables constant measurement of the following parameters:
  • pH of water;
  • content of dissolved oxygen in the water;
  • electrical conductance of the water.
Module is equipped with integrated cooler to lower the sample temperature down to 20°С.

The module control system enables cyclic sampling at more than 4 different points under the preset schedule. The collected data are archived and may further be sent to the upper level via the digital communication protocol.
REGULATION MODULE
ERM
Regulation module is intended for modulated control of the of the module can be achieved when the feed pump module feed water supply into a steam boiler.

Maximal efficiency EPM is jointly used with the ENTROPIE control system.
COOLER BUBBLER
EBR
Cooler-bubbler is intended to cool down hot blowdown water of a single-boiler/multi-boiler unit.

The design enables to control temperature of the water drainage. This can be achieved both through the automatic system of ENTROPIE and locally installed thermostat.
Cooling is achieved through mixing of initial and cooling water.

Cooler bubbler EBR is offered with five sizes, to fit every steam boiler.
REGULATION MODULE
ERM
Regulation module is intended for modulated control of the of the module can be achieved when the feed pump module feed water supply into a steam boiler.

Maximal efficiency EPM is jointly used with the ENTROPIE control system.
STEAM BOILER HOUSES
OUR PROJECTS
ENTROPIE GMBH
Helene-Mayer-Ring 31
80809 Munich

info (@) entropie.de